How To Apply MasterEmaco T 1060 Repair Mortar Concrete must be structurally sound and fully cured. Surface should be prepared following current ICRI Guideline No. 310.2R surface preparation guide. Surface to be repaired must be saturated-surface dry (SSD) with no standing water Precondition material to 70 degrees Fahrenheit (21 degrees Celsius) Add 5.5 pints (2.6 L) of potable water into a clean mixing container Gradually sift in powder, 1/3 of the bag at a time, while mixing continuously at a slow speed Mix for a minimum of 3 minutes to ensure a uniform, lump-free consistency Using a stiff bristle broom, scrub a small quantity of mixed material into the SSD substrate Work material firmly into the bottom and sides of patch. Avoid feather edging. Placement time is approximately 5-10 minutes Finish the completed repair as required Cure with an approved curing compound that complies with ASTM C309 or ASTM C1315 Refer to the MasterEmaco T 1060 technical data guide for more information.